
Building Base Lighting
Consider MDY Deep Flanged for recessed runs beside a building base. The deeper body and wider face flange must both suit the architectural detail.
AI-generated application illustration. Not a completed CRANE project.
Original photograph shows a body detail, not the complete 1000 mm luminaire. The model-specific drawing identifies its profile.
MDY Series · MDY Deep Flanged
Three deeper housing profiles with wider face flanges.
MDY Deep Flanged combines deeper linear housing profiles with wider visible face flanges. Three model cross-sections let you compare the recessed body and surface flange together. Use the selected drawing to coordinate the fixture geometry with the architectural finish and the available installation space.
Project support: Share the model, recess detail, light requirements and project supply.
Features & Specifications
Specifications follow the selected model.
Model Comparison
Compare the three Deep Flanged models by their complete body-and-flange cross-sections and listed configurations.
| Specification | |||
|---|---|---|---|
| Power | 12 W / 18 W / 24 W / 36 W / 48 W | 12 W / 18 W / 24 W / 36 W / 48 W | 12 W / 18 W / 24 W / 36 W / 48 W |
| Luminaire Dimensions | L1000 × body W40 × profile H84 mm | L1000 × body W45 × profile H84 mm | L1000 × body W50 × profile H84 mm |
| Installation Opening (L × W × H) | 1000 × 40 × 85 mm | 1000 × 45 × 85 mm | 1000 × 50 × 85 mm |
| Body width | 40 mm | 45 mm | 50 mm |
| Face-flange width | 65 mm | 70 mm | 75 mm |
| Total profile height | 84 mm | 84 mm | 84 mm |
| Light Source | OSRAM LED | OSRAM LED | OSRAM LED |
| Outer Carton Dimensions (L × W × H) | 103 × 26 × 30 cm | 103 × 26 × 30 cm | 103 × 26 × 30 cm |
| Kit Weight | 2.5 kg | 2.8 kg | 3.2 kg |
MDY Deep Flanged / Optics
Compare beam patterns for the 84 mm high MDY Deep Flanged profiles. Coordinate the 65–75 mm face flange with the finished paving and choose a beam for the pier, wall base or facade bay you want to light.
10° · A narrow spot singles out the pier and reveals the profile of the cornice above.25° · The medium beam illuminates the lower pier with a softer edge around the accent.40° · The beam opens across the wall base and gives the lower facade a wider accent.60° · A wide flood adds a broad accent just above the finished ground level.20° × 55° · The 55° axis runs along the luminaire for a longer accent at the base of the wall.27° × 70° · The wide longitudinal axis spreads light along the facade. The asymmetric section favours the masonry.19° × 38° · The 5° optical offset aims the beam toward the wall from a fixture set level with the paving.
Share your Deep Flanged model, paving section and target area to request photometric data.
Request Optical Data →Facade windows adapted from Amazon Lumberyard Bistro / NVIDIA ORCA under CC BY 4.0.
Applications
Illustrative uses of MDY Deep Flanged for recessed linear lighting beside building bases, landscape walls and entrance piers.
Consider MDY Deep Flanged for recessed runs beside a building base. The deeper body and wider face flange must both suit the architectural detail.
AI-generated application illustration. Not a completed CRANE project.
Linear recessed positions can add an accent layer beside a landscape wall. Consider the Deep Flanged profiles where the surface detail accommodates the visible flange and deeper housing.
AI-generated application illustration. Not a completed CRANE project.
Short recessed linear runs can emphasize entrance piers from ground level. Compare the body and flange geometry with the proposed recess and surrounding finish.
AI-generated application illustration. Not a completed CRANE project.
Technical Documents
Product specifications and technical files for your lighting project.
MDY Deep Flanged · 3 models
Specifications and dimensions for all models on this product page.
Preview DatasheetProject-specific documentation
IES / LDT photometric files, installation guidance and CAD drawings can be requested from our product selection team.
Request Technical FilesBrowse available certificates and check the product and model scope in each document.
FAQ
Selection, installation and documentation questions for MDY Deep Flanged.
This MDY group combines deeper linear housing cross-sections with wider face flanges. It contains three models with separately listed body and flange dimensions.
Deep Flanged includes a visible face flange, while MDY Deep contains non-flanged profiles. Compare the individual drawings for the complete geometry of each candidate.
No such suitability is claimed here. The listed IP67 · IK10 rating is not a vehicle-load or submersible installation approval. Share the site exposure and mounting conditions for review.
Both have a flange, but the listed model sections differ in height and width. Compare the actual body and face drawings with the available recess and finish detail.
No. Confirm the sealing and drainage detail separately, and obtain applicable tested loading conditions before specifying traffic exposure. Neither flange geometry nor IP/IK alone proves those properties.
Include mounting clearance, cable joint, drainage and service access around the selected model. The listed housing height is not the final excavation depth.
Provide the model, ground section and finish, target, quantity, supply and cable route. Request the exact mounting and optical documents before finalizing the project detail.
PROJECT SUPPORT
Share the desired flange detail, available body space and proposed lighting run. Include the MDY Deep Flanged model, quantity and the plan and section drawings.
CURRENT SELECTION · Selected Model: MDY-D4085-6585-57
Our team will review your model, requested configuration and installation requirements, then follow up with the available options.


