Start a Project

Request a Quote.

R Series · R Standard

R Standard Architectural LED Floodlights

Three models with customizable power options

Review R170, R200 and R225 as the intermediate cylindrical housings in the R family. Compare the model data and the appropriate base or U-bracket drawing for the proposed installation.

Power
48 W / 60 W (Customizable)
Maximum Luminous Flux
3,900 lm
LED Quantity
9 or 24 LEDs
Base Mount Size
Ø189.3 × H303 mm
Model3 models

Project support: Review the model, beam, light colour and control for your installation.

Features & Specifications

R Standard Features & Specifications

Power, output and dimensions below follow the selected model.

Cylindrical R Fixture Sizes

R Standard offers three cylindrical housing sizes for directional architectural lighting. The range provides different fixture scales within the R mounting concept.

Select the model alongside the proposed base or bracket arrangement. The complete assembly must fit the surface and the available installation space.

Choose optics with the target geometry and viewing direction in mind. Model size and mounting version should remain clear in the fixture schedule.

Performance & Optics

Power48 W / 60 W (Customizable)
Maximum Luminous Flux3,900 lm
Maximum Luminous Efficacy65 lm/W
LED Quantity9 or 24 LEDs
Lens DiameterØ37 or Ø24 mm
LED Options3535 LED Cree XLamp XP-E OSRAM 3535 RGBW
Beam Angles10° · 15° · 30° · 45° · 65° · 10° × 60° · 20° × 40° · 20° × 60°

Light & Control

Color Temperature (CCT)2700–6000 K (factory-set; specify when ordering)
Light ColorWhite / Red / Green / Blue / Amber / RGB / RGBW
Control OptionsDMX512 · Wireless DMX · ON/OFF
Housing FinishJet Black · Signal White · Anthracite Grey · White Aluminium · Custom colours on request
Warranty5 years
Service Life50,000 h

Mechanical & Electrical

Base Mount DimensionsØ189.3 × H303 mm
U-Bracket DimensionsØ189 × D171 × H229 mm
IP RatingIP66
IK RatingIK10
Input VoltageAC85–265V · 50–60Hz
Operating Temperature−40 °C to +50 °C

Model Comparison

Compare R Standard Models

Compare the listed model differences, then use the corresponding installation reference. The model table is not a project lighting calculation.

Specification
Power48 W / 60 W (Customizable)60 W / 80 W / 100 W (Customizable)80 W / 100 W / 120 W (Customizable)
Maximum Luminous Flux3,900 lm6,500 lm7,800 lm
LED Quantity9 or 24 LEDs12, 24 or 36 LEDs12, 16, 36 or 48 LEDs
Lens DiameterØ37 or Ø24 mmØ37 or Ø24 mmØ45, Ø37 or Ø24 mm
LED Options3535 LED Cree XLamp XP-E OSRAM 3535 RGBW3535 LED Cree XLamp XP-E OSRAM 3535 RGBW3535 LED Cree XLamp XP-E OSRAM 3535 RGBW
Base Mount DimensionsØ189.3 × H303 mmØ221.3 × H311 mmØ247 × H331 mm
U-Bracket DimensionsØ189 × D171 × H229 mmØ221 × D179 × H260 mmØ247 × D199 × H292 mm

Model Selection Guide

R170

Review R170 with the chosen base or bracket drawing and the available fixing space.

R200

For R200, compare the model specification and mounting envelope before preparing the installation detail.

R225

Check R225 against the proposed supporting surface using its own mounting reference, rather than a drawing from R Compact or R Large.

Optical Options

R Standard Optical Distribution

Compare circular and elliptical beam angles for R Standard LED floodlights. View horizontal projection at 0° and estimated beam coverage at 10 m.

30° H × 30° VMedium · Circular distribution
Horizontal beam angle H30°
Vertical beam angle V30°

Target view

Equal scale · H / V
Illustrative beam footprint: 5.36 m wide × 5.36 m high at 10 m.

Perpendicular target plane · Beam shape illustration

Horizontal projection

Side view
Beam coverage at 10 mEstimated at nominal beam angles
Horizontal width≈ 5.36 m
Vertical height≈ 5.36 m

Beam shapes and dimensions are illustrative, not measured photometric data. Actual results depend on the selected optics, luminaire configuration, and installation conditions.

Technical Documents

Technical Documents

Product specifications and technical files for your lighting project.

Product Family Datasheet

R Standard · 3 models

Specifications and dimensions for all models on this product page.

Preview Datasheet

Need More Technical Files?

Project-specific documentation

IES / LDT photometric files, installation guidance and CAD drawings can be requested from our product selection team.

Request Technical Files

FAQ

R Standard Frequently Asked Questions

Questions about R Standard model selection, configuration boundaries and the references needed before specification.

What applications suit R Standard?

R170, R200 and R225 can be considered for facade features, columns and landscape targets where a cylindrical floodlight is suitable. Compare target size, available fixing position and the intended distribution before choosing a model.

How do I select between R170, R200 and R225?

The models have different dimensions and listed power options: R170 lists 48 or 60 W, while R225 lists 80, 100 or 120 W. Check the actual output and mounting drawing for the chosen configuration against the project requirements.

How does R Standard fit between R Compact and R Large?

R Standard occupies the model range between R110–R150 and R260–R300. Select using the dimensions, output and available optics of the individual configuration, together with the space and lighting target; the group label alone is not a performance calculation.

How can the distribution be matched to a facade or column?

Consider the width and height of the target, mounting distance and aiming direction. Check the chosen optic and orientation with configuration-specific photometric data; the interactive illustration is not a substitute for a lighting calculation.

Which mounting dimensions apply to R Standard?

Base and U-bracket versions have separate drawing references. Confirm the chosen version’s fixing footprint, overall size and aiming clearance before the supporting surface is prepared.

What should be verified for color and control?

Confirm the desired light color, electrical version and control system together for the selected R Standard model. Series-level choices should not be assumed to apply to every model or configuration.

What should a project quotation request contain?

Include the target drawing, mounting positions, quantity, model or space constraints and proposed control system. Request the applicable dimension drawing and any available photometric file for the selected configuration.

PROJECT SUPPORT

Discuss Your R Standard Configuration

Include R170, R200 or R225, the intended mounting arrangement and the proposed fixture locations. Attach the drawing version being used and describe the target surface and lighting intent.

CURRENT SELECTION · Selected Model: R170

HELPFUL INFORMATION

  • Light configuration
  • Control requirement
  • Preferred optic
  • Project drawing or reference image
  • Custom product requirements

CUSTOMIZATION SUPPORT

Project-specific customization can be reviewed based on your requirements, including product configuration, housing finish, control method, optics and other feasible modifications.

Our team will review your project information, selected model and customization requirements, then follow up with the available product options.

Request a Quote.

Deutsch