Start a Project

Request a Quote.

T Series · T Compact

T Compact Architectural LED Floodlights

Four models from 3–36 W for architectural lighting

Explore T55, T65, T85 and T100 with their standard and integrated-hood references. Compare the compact cylindrical models and the selected head version before planning a base-mounted installation.

Power
3–6 W (Customizable)
Maximum Luminous Flux
390 lm
LED Quantity
1 pcs
Dimensions Without Hood
Ø59 × L93 × H114 mm
Model4 models

Project support: Review the model, beam, light colour and control for your installation.

Features & Specifications

T Compact Features & Specifications

Power, output and dimensions below follow the selected model.

Compact Heads and Hood Versions

T Compact offers four small floodlight sizes with standard and integrated-hood head forms. The hood is a physical version of the fixture.

Hood Options
Choose the head form and model for the space available at the mounting location. Their complete dimensions matter when coordinating nearby surfaces.

Position and optics should be selected for the desired architectural accent. The hood form can be considered for the viewing arrangement without implying a measured glare value.

Performance & Optics

Power3–6 W (Customizable)
Maximum Luminous Flux390 lm
Maximum Luminous Efficacy65 lm/W
LED Quantity1 pcs
Lens DiameterØ37 mm
Beam Angles10° · 15° · 30° · 45° · 65° · 10° × 60° · 20° × 40° · 20° × 60°

Light & Control

Color Temperature (CCT)2700–6000 K (factory-set; specify when ordering)
Light ColorWhite / Red / Green / Blue / Amber / RGB / RGBW
Control OptionsDMX512 · Wireless DMX · ON/OFF
Housing FinishJet Black · Signal White · Anthracite Grey · White Aluminium · Custom colours on request
Warranty5 years
Service Life50,000 h

Mechanical & Electrical

Dimensions Without HoodØ59 × L93 × H114 mm
Dimensions With HoodØ59 × L113 × H114 mm
Driver Compartment Dimensions22 × 22 × 35 mm (H × W × D)
Net Weight0.65 kg
IP RatingIP66
IK RatingIK10
Input VoltageAC85–265V · 50–60Hz
Operating Temperature−40 °C to +50 °C

Model Comparison

Compare T Compact Models

Compare the listed model differences, then use the corresponding installation reference. The model table is not a project lighting calculation.

Specification
Power3–6 W (Customizable)8–12 W (Customizable)15–24 W (Customizable)15–36 W (Customizable)
Maximum Luminous Flux390 lm780 lm1,560 lm2,340 lm
LED Quantity1 pcs3 pcs6 pcs8 pcs
Lens DiameterØ37 mmØ45, Ø37 or Ø22 mmØ37 or Ø22 mmØ37 or Ø24 mm
Dimensions Without HoodØ59 × L93 × H114 mmØ72 × L115 × H143 mmØ90 × L136 × H164 mmØ109 × L171 × H182 mm
Dimensions With HoodØ59 × L113 × H114 mmØ72 × L136 × H143 mmØ90 × L162 × H164 mmØ109 × L196 × H182 mm
Driver Compartment Dimensions22 × 22 × 35 mm (H × W × D)37 × 22 × 50 mm (H × W × D)30 × 50 × 80 mm (H × W × D)Ø84 × 110 mm (diameter × depth)
Net Weight0.65 kg0.8 kg1.1 kg1.7 kg

Model Selection Guide

T55

Review T55 using the standard or hood drawing that matches the intended fixture version.

T65

For T65, compare the selected head version with the available installation space and viewing direction.

T85

Check T85 against its own drawing; do not use another compact model's mounting dimensions.

T100

Review T100 within the compact group before considering T Large, keeping both model and head version explicit.

Optical Options

T Compact Optical Distribution

Compare circular and elliptical beam angles for T Compact LED floodlights. View horizontal projection at 0° and estimated beam coverage at 10 m.

30° H × 30° VMedium · Circular distribution
Horizontal beam angle H30°
Vertical beam angle V30°

Target view

Equal scale · H / V
Illustrative beam footprint: 5.36 m wide × 5.36 m high at 10 m.

Perpendicular target plane · Beam shape illustration

Horizontal projection

Side view
Beam coverage at 10 mEstimated at nominal beam angles
Horizontal width≈ 5.36 m
Vertical height≈ 5.36 m

Beam shapes and dimensions are illustrative, not measured photometric data. Actual results depend on the selected optics, luminaire configuration, and installation conditions.

Technical Documents

Technical Documents

Product specifications and technical files for your lighting project.

Product Family Datasheet

T Compact · 4 models

Specifications and dimensions for all models on this product page.

Preview Datasheet

Need More Technical Files?

Project-specific documentation

IES / LDT photometric files, installation guidance and CAD drawings can be requested from our product selection team.

Request Technical Files

FAQ

T Compact Frequently Asked Questions

Questions about T Compact model selection, configuration boundaries and the references needed before specification.

Where can T Compact be used?

T55, T65, T85 and T100 can be considered for small architectural details where a cylindrical fixture and adjustable mounting arrangement fit the site. Check target size, aiming clearance and sightlines.

How do T Compact models differ?

They have different dimensions and listed power ranges, from T55 at 3–6 W to T100 at 15–36 W. Compare the actual configuration and drawing with the mounting space and illumination requirement.

When should T Large also be considered?

T Large covers T120 through T200, with different sizes and output options. Compare the exact model, mounting space and required distribution; a larger housing alone does not establish the illuminance on the target.

What should be checked when a hood is required?

Confirm the model-specific hood arrangement and drawing, including the added length and aiming clearance. A reference image does not establish whether a hood is included or compatible with another version.

How should an optic be chosen for a narrow detail?

Match the selected distribution to the feature width and mounting distance, and consider observer sightlines. Confirm the exact optic for the chosen model and light-color configuration.

What should be verified for outdoor connections?

Check the selected configuration’s protection rating and installation requirements, including the cable connection. The luminaire rating alone does not establish protection of the completed connection.

What should a T Compact inquiry contain?

Provide the preferred model or space limit, target, mounting location, quantity and desired light color. Request the appropriate drawing and confirmation of hood, supply and optic.

PROJECT SUPPORT

Discuss Your T Compact Configuration

Specify the T Compact model and whether the standard or integrated-hood version is being considered. Include the base location, sightlines and target details, with the relevant drawing reference.

CURRENT SELECTION · Selected Model: T55

HELPFUL INFORMATION

  • Light configuration
  • Control requirement
  • Preferred optic
  • Project drawing or reference image
  • Custom product requirements

CUSTOMIZATION SUPPORT

Project-specific customization can be reviewed based on your requirements, including product configuration, housing finish, control method, optics and other feasible modifications.

Our team will review your project information, selected model and customization requirements, then follow up with the available product options.

Request a Quote.

Deutsch