Start a Project

Request a Quote.

GL Series · GL Phantom

GL Phantom Architectural LED Floodlights

Four models from 30–240 W for architectural lighting

Explore GL Phantom architectural LED floodlights with finned round housings and U-bracket mounting. Compare four sizes from 30–240 W, review beam shapes and check model-specific dimensions for your project.

Power
30–48 W (customizable)
Maximum Luminous Flux
3,120 lm
Size
Body Ø130 mm; bracket W157 × H148 mm
Model4 models

Project support: Review the model, beam, light colour and control for your installation.

Features & Specifications

GL Phantom Features & Specifications

Power, output and dimensions below follow the selected model.

Finned Round Phantom Housings

GL Phantom uses a finned round housing and U-bracket. Four sizes provide different fixture envelopes for architectural accents and other directional lighting positions.

The selected model determines the housing dimensions, power and output listing. Position the fixture and bracket with the target surface and available clearance in mind.

A visor is shown for some configurations. Specify the required model and accessory together so the proposed assembly can be matched to its own product reference.

Performance & Optics

Power30–48 W (customizable)
Maximum Luminous Flux3,120 lm
Maximum Luminous Efficacy65 lm/W
Beam Angles8° · 12° · 25° · 45° · 60° · 10° × 45° · 15° × 60°

Light & Control

Color Temperature (CCT)2700–6000 K (factory-set; specify when ordering)
Light ColorWhite / Red / Green / Blue / Amber / RGB / RGBW
Control OptionsDMX512 · Wireless DMX · ON/OFF
Housing FinishJet Black · Signal White · Anthracite Grey · White Aluminium · Custom colors on request
Warranty5 years
Service Life50,000 h

Mechanical & Electrical

DimensionsBody Ø130 mm; bracket W157 × H148 mm
IP RatingIP66
IK RatingIK10
Input Voltage85–265 V AC, 50–60 Hz
Operating Temperature−40 °C to +50 °C
Housing MaterialADC12 die-cast aluminum alloy

Model Comparison

Compare GL Phantom Models

Compare the listed model differences, then use the corresponding installation reference. The model table is not a project lighting calculation.

Specification
Power30–48 W (customizable)48–96 W (Customizable)72–144 W (Customizable)150–240 W (Customizable)
Maximum Luminous Flux3,120 lm6,240 lm9,360 lm15,600 lm
DimensionsBody Ø130 mm; bracket W157 × H148 mmBody Ø174.9118 mm; bracket width 200.2798 mmBody Ø219.8497 mm; bracket W245.5883 × H188.5 mmBody Ø280 mm; bracket W308 × H215 mm

Model Selection Guide

GL Phantom 130

Review Phantom 130 using its own housing and visor references. Check the proposed mounting surface before selecting the configuration.

GL Phantom 175

For Phantom 175, compare both the specification column and the corresponding drawing, keeping any visor request linked to this model.

GL Phantom 220

Review Phantom 220 in the available installation space. Include the target surface and viewing direction when requesting configuration support.

GL Phantom 280

Check Phantom 280 as a complete housing-and-bracket assembly. Do not substitute an accessory or drawing from another GL family.

Optical Options

GL Phantom Beam Angles & Light Distribution

Compare circular and elliptical beam shapes for GL Phantom LED floodlights. View horizontal projection at 0° and estimated coverage at 10 m.

25° H × 25° VMedium · Circular distribution
Horizontal beam angle H25°
Vertical beam angle V25°

Target view

Equal scale · H / V
Illustrative beam footprint: 4.43 m wide × 4.43 m high at 10 m.

Perpendicular target plane · Beam shape illustration

Horizontal projection

Side view
Coverage at 10 mEstimated at nominal beam angles
Horizontal width≈ 4.43 m
Vertical height≈ 4.43 m

Beam shapes and dimensions are illustrative, not measured photometric data. Actual results depend on the selected optics, luminaire configuration, and installation conditions.

Technical Documents

Technical Documents

Product specifications and technical files for your lighting project.

Product Family Datasheet

GL Phantom · 4 models

Specifications and dimensions for all models on this product page.

Preview Datasheet

Need More Technical Files?

Project-specific documentation

IES / LDT photometric files, installation guidance and CAD drawings can be requested from our product selection team.

Request Technical Files

FAQ

GL Phantom Frequently Asked Questions

Questions about GL Phantom model selection, configuration boundaries and the references needed before specification.

Where can GL Phantom be used?

GL Phantom can be considered for architectural floodlighting where the round housing and U-bracket suit the support and target. Establish the required coverage and the space for aiming before choosing a model.

How do the GL Phantom sizes compare?

The group contains GL 130, 175, 220 and 280. Their listed power and dimensions differ; select the exact configuration using the installation drawing, target requirements and available fixing space.

Does the finned housing guarantee a longer service life?

No. The appearance of a thermal structure does not establish a service-life advantage. Confirm the specified operating conditions and the actual product documentation for the selected configuration.

How should the U-bracket location be planned?

Check the fixing footprint, bracket clearance, aiming direction and access for connections against the selected model’s drawing. The project engineer should confirm the support is suitable for the installed assembly.

How is an optic chosen for a facade feature?

Match the actual distribution and aiming to the target dimensions and distance. Confirm the optic for the light-color version and request applicable photometric data when calculating illuminance.

Which outdoor connection conditions matter?

Verify the selected model’s protection rating and the requirements for its cable connection. The luminaire rating alone does not establish the protection of the completed connection.

What should a GL Phantom inquiry include?

Provide the target drawing, mounting positions, model or space constraints, quantity and desired color and controls. Request the version-specific drawing and available optical data.

PROJECT SUPPORT

Discuss Your GL Phantom Configuration

Identify the GL Phantom size, target surface and proposed U-bracket location. If a visor is required, specify that request against the exact model and include the relevant installation drawing or site image.

CURRENT SELECTION · Selected Model: GL Phantom 130

HELPFUL INFORMATION

  • Light configuration
  • Control requirement
  • Preferred optic
  • Project drawing or reference image
  • Custom product requirements

CUSTOMIZATION SUPPORT

Project-specific customization can be reviewed based on your requirements, including product configuration, housing finish, control method, optics and other feasible modifications.

Our team will review your project information, selected model and customization requirements, then follow up with the available product options.

Request a Quote.

Deutsch