Start a Project

Request a Quote.

P Series · P Single-Module

P Single-Module Architectural LED Floodlights

Three models from 150–384 W for architectural lighting

Compare three single-module rectangular floodlights for architectural lighting projects. Review W380P, W465P and W615P alongside their drawings, then share the target surface and proposed fixture positions to discuss a suitable configuration.

Power
150–200 W (Customizable)
Maximum Luminous Flux
13,000 lm
LED Quantity
65 pcs
Size
W404 × D123 × H320 mm
Model3 models

Project support: Review the model, beam, light colour and control for your installation.

Features & Specifications

P Single-Module Features & Specifications

Power, output and dimensions below follow the selected model.

Single Rectangular Module

Each P Single-Module fixture uses one rectangular lighting module. Three housing sizes provide options for projects requiring this format at different mounting scales.

The complete housing and bracket dimensions belong to the selected model. Coordinate that envelope with the proposed fixture position before choosing power and optics.

Pair the model with its intended light color and control configuration in the project schedule. A dual-module fixture belongs to the separate P Dual-Module group.

Performance & Optics

Power150–200 W (Customizable)
Maximum Luminous Flux13,000 lm
Maximum Luminous Efficacy65 lm/W
LED Quantity65 pcs
Beam Angles11° · 23° · 43° · 69° · 11° × 41° · 22° × 39°

Light & Control

Color Temperature (CCT)2700–6000 K (factory-set; specify when ordering)
Light ColorWhite / Red / Green / Blue / Amber / RGB / RGBW
Control OptionsDMX512 · Wireless DMX · ON/OFF
Housing FinishJet Black · Signal White · Anthracite Grey · White Aluminium · Custom colours on request
Warranty5 years
Service Life50,000 h

Mechanical & Electrical

DimensionsW404 × D123 × H320 mm
IP RatingIP66
IK RatingIK10
Input VoltageAC85–265V · 50–60Hz
Operating Temperature−40 °C to +50 °C
MaterialsADC12 aluminum alloy + weather-resistant silicone gasket + tempered glass

Model Comparison

Compare P Single-Module Models

Compare W380P, W465P and W615P before reviewing the drawing for your proposed mounting position. A model's maximum listed output is not a project lighting calculation.

Specification
Power150–200 W (Customizable)200–240 W (Customizable)288–384 W (Customizable)
Maximum Luminous Flux13,000 lm17,280 lm24,960 lm
LED Quantity65 pcs102 pcs96 pcs
DimensionsW404 × D123 × H320 mmView drawing W490 × D129 × H351 mmView drawing W643 × D140 × H355 mmView drawing

Optical Options

P Single-Module Beam Angles & Light Distribution

Choose from six circular and elliptical optics for P Series architectural LED floodlights. Compare facade lighting beam shapes, horizontal projection at 0° and illustrative beam dimensions at 10 m.

23° H × 23° VMedium · Circular distributionArchitectural features and defined facade sections.
Horizontal beam angle H23°
Vertical beam angle V23°

Target view

Equal scale · H / V
Illustrative beam footprint: 4.07 m wide × 4.07 m high at 10 m.

Perpendicular target plane · Beam shape illustration

Horizontal projection

Side view
Illustrative beam footprintAt a projection distance of 10 m
Horizontal width≈ 4.07 m
Vertical height≈ 4.07 m

Beam shapes and dimensions are illustrative, not measured photometric data. Actual results depend on the selected optics, luminaire configuration, and installation conditions.

Technical Documents

Technical Documents

Product specifications and technical files for your lighting project.

Product Family Datasheet

P Single-Module · 3 models

Specifications and dimensions for all models on this product page.

Preview Datasheet

Need More Technical Files?

Project-specific documentation

IES / LDT photometric files, installation guidance and CAD drawings can be requested from our product selection team.

Request Technical Files

FAQ

P Single-Module Frequently Asked Questions

Selection notes for the P single-module format, its listed configuration options and the documents needed for project review.

Where does a P Single-Module floodlight fit in an architectural project?

Its rectangular single-module form can be considered for directional facade illumination where the mounting position accommodates the fixture and bracket. Define the illuminated area and available aiming positions before selecting a model and optic.

How do W380P, W465P and W615P differ?

They have different housing dimensions and listed power ranges: W380P is 150–200 W, W465P is 200–240 W, and W615P is 288–384 W. Compare the exact configuration and available mounting space alongside the lighting calculation.

When should the single-module and dual-module groups be compared?

The single-module group comprises W380P, W465P and W615P; the dual-module group comprises W465DP and W615DP. Compare the model-specific power, dimensions, fixing structure and required distribution rather than assuming either group is suitable from its module count alone.

How should the optic be matched to a facade?

Consider the width and height of the target, the mounting distance and the orientation of any elliptical distribution. Confirm the optic for the exact light-color and electrical configuration and use applicable photometric data for the lighting calculation.

What installation space is needed for W615P?

The listed comparison dimensions are W643 × D140 × H355 mm. Check the dimensioned drawing for the ordered version, bracket position and aiming clearance before preparing the fixing surface; the comparison size does not establish the necessary service clearance.

Can the same control system be used with every P configuration?

Do not assume so. Confirm the light color, electrical version and control arrangement together for the chosen model. Series-level options do not establish that every combination is available.

What should accompany a P Single-Module project inquiry?

Provide the target dimensions, proposed mounting locations, quantity, desired distribution and light color. Request the model-specific drawing, electrical details and available photometric information for the intended configuration.

PROJECT SUPPORT

Discuss Your P Single-Module Configuration

Tell us which P Single-Module model you are considering and where the rectangular fixture will be installed. Include a façade elevation or site image, the available mounting space and the intended lighting effect.

CURRENT SELECTION · Selected Model: W380P

HELPFUL INFORMATION

  • Light configuration
  • Control requirement
  • Preferred optic
  • Project drawing or reference image
  • Custom product requirements

CUSTOMIZATION SUPPORT

Project-specific customization can be reviewed based on your requirements, including product configuration, housing finish, control method, optics and other feasible modifications.

Our team will review your project information, selected model and customization requirements, then follow up with the available product options.

Request a Quote.