Start a Project

Request a Quote.

R Series · R Large

R Large Architectural LED Floodlights

Two large models with customizable power options

Compare R260 and R300, the two larger cylindrical housings in the R range. Review the references available for each mounting version before developing the installation detail.

Power
100 W / 120 W / 150 W (Customizable)
Maximum Luminous Flux
9,750 lm
LED Quantity
18, 20, 28, 48 or 60 LEDs
Base Mount Size
Ø283.8 × H350 mm
Model2 models

Project support: Review the model, beam, light colour and control for your installation.

Features & Specifications

R Large Features & Specifications

Power, output and dimensions below follow the selected model.

Large Cylindrical R Fixtures

R Large contains two cylindrical floodlight models with distinct housing and support dimensions. The complete assembly is relevant to architectural mounting positions.

Choose the model and mounting version together so the required clearance and fixture orientation can be assessed as one detail.

Select the beam for the intended surface and viewing direction. A larger cylinder does not, by itself, specify the reach of the lighting effect.

Performance & Optics

Power100 W / 120 W / 150 W (Customizable)
Maximum Luminous Flux9,750 lm
Maximum Luminous Efficacy65 lm/W
LED Quantity18, 20, 28, 48 or 60 LEDs
Lens DiameterØ45, Ø37 or Ø24 mm
LED Options3535 LED Cree XLamp XP-E OSRAM 3535 RGBW
Beam Angles10° · 15° · 30° · 45° · 65° · 10° × 60° · 20° × 40° · 20° × 60°

Light & Control

Color Temperature (CCT)2700–6000 K (factory-set; specify when ordering)
Light ColorWhite / Red / Green / Blue / Amber / RGB / RGBW
Control OptionsDMX512 · Wireless DMX · ON/OFF
Housing FinishJet Black · Signal White · Anthracite Grey · White Aluminium · Custom colours on request
Warranty5 years
Service Life50,000 h

Mechanical & Electrical

Base Mount DimensionsØ283.8 × H350 mm
U-Bracket DimensionsØ284 × D218.69 × H330 mm
IP RatingIP66
IK RatingIK10
Input VoltageAC85–265V · 50–60Hz
Operating Temperature−40 °C to +50 °C

Model Comparison

Compare R Large Models

Compare the listed model differences, then use the corresponding installation reference. The model table is not a project lighting calculation.

Specification
Power100 W / 120 W / 150 W (Customizable)120 W / 150 W / 200 W (Customizable)
Maximum Luminous Flux9,750 lm13,000 lm
LED Quantity18, 20, 28, 48 or 60 LEDs24, 36, 60 or 72 LEDs
Lens DiameterØ45, Ø37 or Ø24 mmØ45, Ø37 or Ø24 mm
LED Options3535 LED Cree XLamp XP-E OSRAM 3535 RGBW3535 LED Cree XLamp XP-E OSRAM 3535 RGBW
Base Mount DimensionsØ283.8 × H350 mmØ325.5 × H367 mm
U-Bracket DimensionsØ284 × D218.69 × H330 mmØ325 × D230 × H394 mm

Model Selection Guide

R260

For R260, check which mounting drawings are available. If the proposed version lacks a dimensional reference, request it before finalising the fixing detail.

R300

Review R300 with the base or U-bracket drawing appropriate to the intended installation. Keep the selected version explicit in the project schedule.

Optical Options

R Large Optical Distribution

Compare circular and elliptical beam angles for R Large LED floodlights. View horizontal projection at 0° and estimated beam coverage at 10 m.

30° H × 30° VMedium · Circular distribution
Horizontal beam angle H30°
Vertical beam angle V30°

Target view

Equal scale · H / V
Illustrative beam footprint: 5.36 m wide × 5.36 m high at 10 m.

Perpendicular target plane · Beam shape illustration

Horizontal projection

Side view
Beam coverage at 10 mEstimated at nominal beam angles
Horizontal width≈ 5.36 m
Vertical height≈ 5.36 m

Beam shapes and dimensions are illustrative, not measured photometric data. Actual results depend on the selected optics, luminaire configuration, and installation conditions.

Technical Documents

Technical Documents

Product specifications and technical files for your lighting project.

Product Family Datasheet

R Large · 2 models

Specifications and dimensions for all models on this product page.

Preview Datasheet

Need More Technical Files?

Project-specific documentation

IES / LDT photometric files, installation guidance and CAD drawings can be requested from our product selection team.

Request Technical Files

FAQ

R Large Frequently Asked Questions

Questions about R Large model selection, configuration boundaries and the references needed before specification.

Where can R Large floodlights be considered?

R260 and R300 can be considered for larger architectural features where their cylindrical housings and mounting arrangements fit the site. Confirm the target geometry and required illuminance with the proposed optic and location.

What distinguishes R260 from R300?

R260 lists 100, 120 and 150 W options; R300 lists 120, 150 and 200 W options. Their housings and listed maximum outputs differ. Compare the actual version and mounting drawing as well as the power option.

How should R Large be compared with D Large?

R Large uses cylindrical housings and has base and U-bracket references; D Large contains D230 and D300 round-head models. Compare the exact drawings, output and optical configuration for the site rather than assuming one series has a universal performance advantage.

How do distance and optic affect a large target?

Distance, aiming and distribution affect the light reaching the target. Use the selected configuration’s photometric data and a calculation to assess coverage, target illuminance and fixture quantity; the nominal wattage alone cannot establish a throw distance.

What installation checks matter for R260 and R300?

Check the drawing for the selected mounting arrangement, available clearance, access and fixing footprint. The project engineer should confirm that the supporting structure is suitable for the installed assembly and site conditions.

What should be checked for outdoor maintenance?

Confirm the exact configuration’s protection rating and installation instructions, including connections and access for maintenance. A rating by itself does not describe the condition of the mounting surface or the completed connection.

What should be supplied with an R Large inquiry?

Provide the target and mounting drawings, required quantity, desired optical and control configuration, and the preferred base or bracket arrangement. Request applicable dimensions and photometric files for the proposed model and version.

PROJECT SUPPORT

Discuss Your R Large Configuration

Share R260 or R300, the intended mounting version and the available support space. Request any missing mounting drawing and include target geometry rather than relying on the model size to describe the required effect.

CURRENT SELECTION · Selected Model: R260

HELPFUL INFORMATION

  • Light configuration
  • Control requirement
  • Preferred optic
  • Project drawing or reference image
  • Custom product requirements

CUSTOMIZATION SUPPORT

Project-specific customization can be reviewed based on your requirements, including product configuration, housing finish, control method, optics and other feasible modifications.

Our team will review your project information, selected model and customization requirements, then follow up with the available product options.

Request a Quote.

Deutsch